Application: SCD Probiotics Technology used to improve the efficiency of urban wastewater treatment facility
Customer: Przedsiębiorstwo Gospodarki Komunalnej i Mieszkaniowej
Where: Turek, Poland
When: Since 2005
SCD Products: Customized solution using SCD Bio Klean™
SCD Licensee: ProBiotics Polska
Magdalena Górska
Bratuszyn 21 62 - 720 Brudzew
Tel. / fax : +48 (0) 632 798 725
www.probiotics.pl
E-mail: biuro@em-world.pl

Customer Problem
The wastewater treatment plant in Turek has a designed daily capacity of approximately 15,750 cubic meters/day. Daily influence reaches from 8,500 - 10,500 cubic meter / day.

As is common in many wastewater treatment facilities, the customer faced numerous challenges with the operational efficiency of the system including wastewater quality, foul odors negatively affecting the surrounding communities, difficulties with sludge removal, difficult working conditions for staff, and clogged drains due to sludge.

Goal
All outflow standards established by regulations must be met; further reduction of baseline outflow results are desired (see Table 1 and Table II respectively).

Table 1: Environmental Regulation Standards

Parameter
Unit
Outflow Standard
Chemical Oxygen Demand (COD)
mg/dm3
≤ 125
Biological Oxygen Demand (BOD)
mg/dm3
≤ 15
Total Suspended Solid (TSS)
mg/dm3
≤ 35
Nitrogen (N)
mg/dm3
≤ 15
Phosperous (P)
mg/dm3
≤ 2

Table II: Mean Wastewater Characteristics (2004) Prior to SCD Probiotics Applications

Daily inflow
[m3/day]
Production [t/year]
Inflow [mg/dm3]
Screenings
Sand
Sludge
TSS
COD
BOD
P
N
8435
158.1
107.8
711.0
237.2
802.6
534.5
13.5
60.1
Outflow [mg/dm3]
TSS
COD
BOD
P
N
16.4
58.4
8.1
1.1
11.3

Methodology
SCD Bio Klean is added to the sludge once it is separated from the water inflow. A portion of sludge is re-circulated to the system at the beginning of the process.

Results
Significant improvement in all outflow parameters occurred (40 - 65% reduction in outflow parameters compared to mean baseline parameters).

Table III: Mean Wastewater Characteristics (2008) After SCD Probiotics Application

Daily influence
[m3/day]
Production [m3/day]
Influence [mg/dm3]
Screenings
Sand
Sludge
TSS
COD
BOD
P
N
8222.0
11.7*
105.0
741.1
318.6
970
458
13.3
64.6
Effluence [mg/dm3]
TSS
COD
BOD
P
N
5.0
35.8
2.7
0.5
5.6

Results (continued)
In addition, the following benefits were achieved as a result of the SCD Probiotics application, positively impacting the operational and financial performance of the wastewater treatment facility.

  1. The structure of the sludge changed from greasy to porous. Consequently, transportation of the sludge became easier.
  2. The pathogenic microbes were conceivably decreased which accounted for the removal of foul odor and improved sanitary working conditions.
  3. The amount of utilized coagulation agents was reduced by 35 - 40%.
  4. The lime previously applied to the sludge was entirely removed from the hygienisation process.
  5. The pontoons formerly used to cover the open digestion chambers are no longer in use.
  6. he clogging of the drainage system of sludge deposit sites was eliminated.
  7. The interest in applying sludge for farming needs and soil restoration significantly increased.

Cost Analysis: SCD Probiotics retail price of $7.57/gallon was used for the following information. This facility has an average daily inflow of 9500m3 or 2,513,175 gallons of waste water to be treated. The daily treatment dosage prescribed is 1:165000 with 15 gallons of SCD Bio Klean™ applied as the treatment. This is an investment of $115/day to maintain the microbial ecology of the waste water treatment system with beneficial microorganisms or Probiotics. This application breaks down to a cost of $0.00005/gallon of waste water to be treated.

FOR PRODUCT ORDERS

USA Distributors / Wholesalers


Please call 913.541.9299 to place your order with your personal account coordinator.

International Partners


Find out more about becoming an international partner. Current partners should contact their account coordinator for sales or customer support; or customerservice@
SCDProbiotics.com
.

USA Retail Customers


Click here to access or create your account.

German Retail Customers


Please go to www.SCDProbiotics.de to place your order directly with SCD Probiotics Germany.